Material characteristics of expanding dilator sheath公開時間:2025-04-03 13:12 Dilated sheath tube is mainly used for vascular intervention, urology, digestive endoscopy and other operations.
According to different surgical needs, the appropriate material should be selected when purchasing the dilated sheath tube. The material of the tube directly affects its flexibility, friction coefficient, flexural resistance and biocompatibility. Material differentiation 1.PU advantage: - High flexibility, suitable for tortuous paths, such as peripheral blood vessels, ureters - moderate flexural resistance, Bitfluron is good, but not as good as nylon - medium friction coefficient, need hydrophilic coating assistance - good biocompatibility, not prone to thrombosis or inflammation due to its Disadvantages: Long-term indwelling may age, such as the central venous catheter sheath 2. PTFE Advantage: - Very low friction coefficient, instruments can pass smoothly, such as balloons, stents - high rigidity, good push force conduction, but easy to break in the bending site - excellent biocompatibility, strong anti-thrombotic performance Disadvantages: poor flexibility 3. PE Advantages: - Hardness between polyurethane and Teflon - good wear resistance, suitable for repeated equipment through - low cost, cost-effective Disadvantages: - Easy deformation at high temperature, not suitable for high-temperature sterilization repeated use 4. PA Advantages: - High strength, high pressure resistance - excellent fracture resistance, suitable for large cavity diameter sheath - high rigidity, but may increase vascular damage Disadvantages: poor flexibility, not suitable for tortuous paths 5.Composite material (multi-layer design) Features: * Outer layer: polyurethane/nylon, provides structural support * Inner layer: Teflon/hydrophilic coating, reduces friction * Advantages: balance flexibility and passability 6.Hydrophilic coating Features: * The friction coefficient is significantly reduced after encountering water, good lubricity * reduces vasospasm or mucosal damage, good passability * Disadvantages: the coating may be stripped, and violent operation needs to be avoided Material selection suggestion 1. Vascular intervention: Teflon (short sheath) or composite material (long sheath) + hydrophilic coating is preferred 2. Tortuous stripping: polyurethane sheath + hydrophilic coating 3.High pressure/large cavity diameter: nylon sheath 4.Cost sensitive: polyethylene sheath (single use) * In the actual selection, it is necessary to combine the compatibility of different device brands, lesion complexity, and operating habits, and refer to the mechanical performance data provided by the manufacturer. Kunshan Bofa Plastic can provide customized production of expansion sheath tube 声明:此篇为我的网站原创文章,转载请标明出处链接:https://www.bovaplastic.com/jp/shkguy/177.html
記事の分類:
行业新闻
|